SOHAM CONSULTING SERVICES

Metals and Alloys Testing

Sections made of various materials are rolled or drawn out of semi-finished goods such as billets or bars, and in many cases they are also welded from bar material. They are used in a vast number of applications, requiring a wide variety of mechanical tests. Together with the reinforcing steel and ribbed reinforcement bars (re bars) so vital to civil engineering they form a group of important structural materials, which in the case of concrete-reinforcing steel, are subject to regulatory control.
List of Material Covered are as follow: -

Reinforcement Bars & TMT Steel:

1 % Elongation Upto 36 mm Dia of Reinforcement Steel IS 1608 (Part 1)

2 Bend Test Upto 36 mm Dia of Reinforcement Steel IS 1599,IS 1786

3 Nominal Unit Weight Upto 40 mm Dia of Reinforcement Steel IS 1786

4 Rebend Up To 36 mm Dia of Reinforcement Steel IS 1786, IS 1599

5 Ultimate Tensile Strength Upto 36 mm Dia of Reinforcement Steel IS 1888

6 Yield Stress Upto 36 mm Dia of Reinforcement Steel IS 1608 (Part 1)

Mild And Medium Tensile Steel Bar:

7 Ultimate Tensile Strength Up To 36 mm Dia Of Mild & Medium Steel IS 1608 (Part 1)

8 Bend Test Upto 36 mm Dia Of Mild & Medium Steel IS 1599

9 Nominal Unit Weight Upto 40 mm Dia Of Mild & Medium Steel IS 1732

10 Yield Stress Upto 40 mm Dia Of Mild & Medium Steel IS 1608 (Part 1)

Reinforcement Mild Steel & Medium Tensile Bars and HSD Bars Structural Steel:

11 Ultimate Tensile Strength Of HSD Bars Structural Steel IS 1608 (Part-1)

12 Elongation Of HSD Bars Structural Steel IS 1608 (Part-1)

13 Yield Stress of HSD Bars Structural Steel IS 1608 (Part-1)

Structural Steel:

14 Bend Test Thickness Upto 40 mm Of Structural Steel IS 1599

15 Ultimate Tensile Strength Thickness Upto 40mm Of Structural Steel IS 1608 (Part-1)

16 Yield Stress Thickness Upto 40 mm Of Structural Steel IS 1608 (Part-1)

Hard Drawn Steel Wire:

17 Yield Stress Upto 10 mm Dia of Hard Drawn Steel Wire IS 1608 (Part-1)

18 Elongation Over Gauge Length of 8D Upto 10 mm of Hard Drawn Steel Wire IS 1608 (Part-1)

19 Electrical Resistivity of Soil Test IS 1608 (Part-1)

Uncoated Stress Relived Low Relaxation Seven Wire Strand For Prestressed Concrete:

1 0.2 % Proof Load for 12.7 mm and 15.2 mm Dia IS 1608 (Part-1)

2 Elongation For 12.7 mm and 15.2 mm Dia IS 1608 (Part-1)

3 Nominal Area For 12.7 mm and 15.2 mm Dia IS 14268

4 Nominal Mass for 12.7 mm and 15.2 mm Dia IS 14268

5 Ultimate Breaking Load for 12.7mm and 15.2 mm Dia IS 1608 (Part-1)

Chemical Tests & Parameters:

1 Carbon IS 228

2 Manganese IS 228

3 Phosphorus IS 228

4 Silicon IS 228

5 Sulphur IS 228